해양사업

AUTOPILOT

NAVIPILOT4500N Marine Autopilot은 선박을 안전하고 효율적으로 조종하기 위하여 진보된 선박 조타 네트워크 기술을 사용합니다.
혁신적인 NAVIPILOT4500N은 선박의 부하특성과 기상조건에 대하여 자동으로 맞추어 자체적으로 세부조정이 가능합니다.

Rudder Angle Feedback Unit

ENVIRONMENT
Ambient temperature range (operation) -15° C to +55° C
Ambient temperature range (storage) -25° C to +70° C
Protection grade (installed) IP32 to DIN 40050
Standard magnetic compass 0.40m
Environmental testing in accordance with EN 60945 (IEC 945 +A1)
DIMENSIONS
Front panel Dimensions 288 x 144 mm to DIN Standard
Installation Depth 150 MM
Weight 1.5 kg
Front Panel Sealed Foil Keyboard, illuminated
Display Graphic Liquid Crystal, illuminated
STEERING CONTROL UNIT
Protection grade IP32 to DIN 40050
Magnetic clearance I0.4 m
Dimensions 151 mm Height, 392 mm Width, 425 mm Depth
Weight 3 kg
Power requirements 24 VDC (18 V to 36 V)
Maximum ripple content 4 V pp, extreme values should not exceed 36 V or fall below 18 V
Power consumption 10 W max
Reverse polarity protection Built-in
Cable connection Clamp-type terminals
POWER REQUIREMENTS
Max ripple content 4 V pp, extreme values should not exceed 36 V or fall below 18 V
Power consumption 10 W max
Reverse polarity protection Built-in
INPUTS
Rudder angle feedback signal ±10 V ±120° max rudder angle potentionmeter resistance 2kW
Power consumption 10 W max
Flux gate for magnetic compass sine/cosine, C. Plath product
NAV/TRACK interface NMEA 0183 (sentence selectable) from GPS, INS and others
Speed input 200 p/nm or NMEA 0183
180° turn command Port and starboard
Gyro/magnetic selection
Override status
Mute
Gyrocompass or electronic flux gate Two NMEA 0183
Central alarm NMEA 0183
Status signals AUTO, NFU, Helm, Remote, Ext System

OUTPUTS

DC Solenoid Valves
Outputs Two for port, two for starboard (solid-state relays)
Type Plus or minus switching
Voltage 12 VDC to 110 VDC
Rating 2.0 A max.
Additional outputs Optional
Inputs "Pump on" sense contact closure inputs
AC Solenoid valves
Outputs Two for port, two for starboard (solid-state relays)
Voltage 24 VAC to 230 VAC
Rating 1.0 A max.
Additional outputs Optional
Inputs "Pump on" sense contact closure inputs
POWER REQUIREMENTS
Max Ripple Content 4 V pp, extreme values should not exceed 36 V or fall below 18 V
Power Consumption 10 W max
Reverse Polarity Protection Built-in
PROPORTIONAL RUDDER ORDER/ ERROR
Outputs 80 mV/° to 350 mV/° (isolated) or 4 mA to 20 mA (isolated)
Additional outputs Optional
OUTPUTS AND INTERFACES
Heading NMEA 0183
Heading gyro HEHDT at 10 Hz
Navigation system data NSD at 1 Hz
Heading magnetic HCHDT or HCHDM or HCHDG at 10 Hz
STATUS AND ALARM
System alarm
Off course alarm*
Override alarm*
Gyro/mag status*
Ext system status*
Deadman's control*
Mute*

* max 4 outputs selectable

POWER FAILURE ALARM
Primary supply Potential-free contacts
Backup supply 2 A maximum current, 250 V maximum voltage